Open the interactive guide to see each step on your Dome.
Please follow these troubleshooting steps in order.
-
Open the rear dock
Let the oven cool fully. Make sure you can reach the front and back. To lift it, use four people and the base hand holds.
Have a T25 Torx screwdriver, 10 mm spanner, new stone probe and display battery ready.
At the back, remove the two T25 screws and the rear dock panel.
-
Unplug the stone probe
Remove the display. Behind the PCB, press the clip under the middle plug and pull the plug out.
-
Replace the stone probe
With a 10 mm spanner, unscrew the stone probe from the dock roof and pull it down. Push the new probe up into the hole and tighten it.
-
Reconnect and close the dock
Plug the new probe into the middle socket. Refit the rear dock panel with its two T25 screws. Refit the display with a fully charged battery and check if the display is showing any error messages.
If you have any further problems, contact the Gozney Team.