Open the interactive guide to see each step on your Dome.
Please work through these troubleshooting steps in order.
-
Open the rear dock
Let the oven cool fully. Make sure you can reach the front and back. To lift it, use four people and the base hand holds.
Have a T25 Torx screwdriver, 13 mm spanner, new air probe and display battery ready.
At the back, remove the two T25 screws and the rear dock panel.
-
Unplug the air probe
Remove the display. Behind the PCB, press the clip under the smallest plug, on the right, and pull the plug out.
-
Replace the air probe
In the oven chamber, unscrew the air probe from the back wall with a 13 mm spanner. Pull it out with its wire. Push the new probe's wire through the hole and tighten the probe.
-
Reconnect and close the dock
Plug the new probe into the PCB. Refit the rear dock panel with its two T25 screws. Refit the display with a fully charged battery and check if the display is showing any error messages.
If you have any further problems, contact the Gozney Team.